Zebra Stripe Technical Information Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 119
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
The Label Available Sensor functions only when the printer is set to Peel-Off
mode. This mode requires that the Peel-Off option be installed in the printer.
This sensor is NOT installed on printers without this option.
See Figure 5.6 for the location of the Label Available Sensor. When the sensing
beam is broken, the printer will be inhibited from printing or feeding (in
Peel-Off mode only). It may, however, accept additional label formats if the
buffer is not full. When the label is removed, the next label prints automatically.
There is no sensitivity adjustment for the Label Available Sensor. Sensors are
attached and aligned at the factory when the Peel-Off option is installed. If you
encounter problems, check the alignment of the sensor components: they should
point directly at one another. Verify that the format sent contains the Peel-Off
Mode command.
The following topics provide the service technician with three (3) maintenance
procedures dealing with the removal, replacement, and adjustment of the Printhead.
Choose the appropriate set of procedures for your printhead, type A, B, or C, by
comparing figures 5.8, 5.10, and 5.12 to your printer.
Printhead adjustments are required when replacing the printhead element
assembly or when attempting to improve print quality and adjust parallelism.
Keep in mind that the overall goal is to provide the best print quality for a given
Media and Ribbon (if used).
If your printhead assembly is type A, refer to Figures 5.7 and 5.8.
If your printhead is type B, refer to Figures 5.9 and 5.10.
If your printhead assembly is type C, refer to Figures 5.11 and 5.12.