Zebra Stripe Technical Information Page 66

  • Download
  • Add to my manuals
  • Print
  • Page
    / 119
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 65
1. Insure that the printer is OFF and that Media and Ribbon are loaded.
2. Remove any used ribbon from the Ribbon Take-up Spindle by pressing the
button on the end of the Spindle and sliding off the ribbon.
3. Remove the Cover from the Electronics Compartment and locate the Spindle
Tension Adjustment Potentiometer (RV3) on the Main Logic Board.
See Figure 5.8 for the location of RV3.
4. Locate the Ribbon Take-Up Motor behind the upper left corner of the Main
Logic Board and check the style of Power Lead connection at the motor.
If removable spade lug connectors are used, continue with Step 11 of the
adjustment procedure on the following page. If the power leads are soldered
to connecting pins on the motor, continue with the procedure.
5. Use tape to attach the Mylar strip (part # 01776) to the Ribbon Take-up Spindle.
Wind the Mylar strip around the spindle three full turns counterclockwise.
6. Attach a 1000 gram spring scale to the end of the Mylar tape and hold it
stationary. See Figure 5.18.
7. Press the PAUSE Key and turn the power ON. Self test labels will feed out
and the spring scale indicator will move.
8. While reading the spring scale, adjust potentiometer RV3 clockwise or
counterclockwise and set the tension to a value between 450 and 550 grams.
9. When correct tension is obtained, press the PAUSE Key to stop the label
printing process and remove the spring scale and Mylar strip.
10. Reload the media and ribbon and remount the Electronics Cover.
44868L Page 5-27