Zebra Stripe Technical Information Page 21

  • Download
  • Add to my manuals
  • Print
  • Page
    / 119
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 20
“Darkness” value specified on the Configuration Printout.
The resulting numeric value (0 to 30) is the best darkness value for that specific
Media/Ribbon combination.
The plus or minus value selected can be entered while performing a Media
Darkness Adjustment. Enter the PLUS value by pressing the UP (FEED) Key, or
enter the MINUS value by pressing the DOWN (CANCEL) Key the appropriate
number of times. Refer to the user’s guide for more information.
Optionally, the required Darkness adjustment value can be programmed into the
ZPL II formats sent to the printer.
MODE Key Self Test
This Self Test places the printer in a
Communications Diagnostics Mode.
Press the MODE Key while turning
the AC power switch ON, then send
a label format to the printer. In this
mode, the printer prints the ASCII
characters and their corresponding
hexadecimal values for any data
received from the host computer.
See the example in Figure 3.4.
NOTE: Turn the Printer Power OFF to
exit this Self Test.
FEED, PAUSE, and CANCEL Keys
If these three keys are pressed at the same time and the Power is turned ON, the
printer enters the Media Sensor and Ribbon Sensor Adjustment Mode. See
Section 5 for these adjustments.
Figure 3.4 MODE Key Self Test Printout
Printer Diagnostics Stripe Maintenance Manual: Volume 1
Page 3-4 44868L
Page view 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 118 119