Zebra 105SL Specifications Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 246
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 3-5
TROUBLESHOOTING SECTION 3
3$86(.H\6HOI7HVW
1. The initial self test prints 15 labels at a speed of 2 per second, then automatically
PAUSES the printer. When the PAUSE key is pressed, an additional 15 labels print.
See Figure 3-2.
2. While the printer is PAUSED, press the CANCEL key once to alter the self test. When
the PAUSE key is pressed, the printer prints the self test labels at 6 per second.
Fifteen additional labels are printed each time the PAUSE key is pressed.
3. While the printer is PAUSED, press the CANCEL key a second time to change the self-
test print speed back to 2 per second. When the PAUSE key is pressed, the printer
prints 50 labels.
4. While the printer is PAUSED, press the CANCEL key a third time to change the self-
test print speed to 6 per second. When the PAUSE key is pressed, the printer prints
50 labels.
5. While the printer is PAUSED, press the CANCEL key a fourth time to change the self-
test print speed to the printer’s fastest speed. When the PAUSE key is pressed, the
printer prints 15 labels.
)(('.H\6HOI7HVW
NOTE: The CANCEL Key Self Test should be performed prior to this self test.
Information on the printed configuration label (CANCEL Key Self Test) is used with the results
of this self test to determine the best darkness setting for a specific media/ribbon combination.
The FEED key self test label prints out at various positive and negative darkness settings
relative to the darkness value shown on the configuration label. See the label example in
Figure 3-3. Inspect these labels and determine which one has the best darkness setting for
the application. This value can be entered into the printer by configuring the “Setting
Darkness” parameter found in the configuration section of the User’s Guide.
The value printed on the selected test label is added to (+) or subtracted from () the
“Darkness” value specified on the configuration label.
The resulting numeric value, 0 to 30, that is best for that specific media/ribbon combination
should be entered as the “Darkness” parameter.
Figure 3-2. PAUSE Key Test Sample Label
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 245 246

Comments to this Manuals

No comments