32056L Rev. 2 12/4/01 105SL Maintenance Manual Page 2-27
OPERATION OVERVIEW SECTION 2
The first attempt to change one of these parameters (pressing the () or (+) keys) requires you
to enter a four-digit password. This is done via the “ENTER PASSWORD” display. The () key
changes the selected digit position. The (+) key increases the selected digit value. After
entering the password, press the NEXT/SAVE key. The parameter you are trying to change is
displayed. If the password was entered correctly, you can now change the value.
The default password value is 1234. The password can be changed using the ^KP (Define
Password) ZPL II instruction.
NOTES: Once the password has been correctly entered, it need not be entered
again unless you leave and re-enter the programming mode using the
SETUP/EXIT key.
You can disable the password protection feature so that it no longer
prompts you for a password by setting the password to ØØØØ via the
^KPØ ZPL/ZPL II command. To re-enable the password-protection feature,
send the ZPL/ZPL II command ^KPx, where “x” can be any number, 1–4
digits in length, except Ø.
/HDYLQJWKH6HWXS0RGH
You can leave the setup mode at any time by pressing the SETUP/EXIT key. The SAVE
CHANGES display appears. There are five choices, described below. Press the (+) or ()
key to display the sequence of choices. When your choice is displayed on the LCD, press
the NEXT/SAVE key to save settings.
PERMANENT: saves the current settings. Values are stored in the printer even when power
is turned OFF.
TEMPORARY: saves the current settings until changed again or until power is turned off.
CANCEL: cancels all setting changes made since entering the programming mode except
the darkness and tear-off settings, if they were changed.
LOAD DEFAULTS: loads factory default settings. Refer to the User’s Guide for default
values.
NOTE: If you load factory default settings, you may have to perform a media and
ribbon sensor calibration.
LOAD LAST SAVE: reloads the settings made during the last permanent save.
6(77,1*35,173$5$0(7(56
6HWWLQJ'DUNQHVV
Darkness, also known as burn duration, settings are dependent upon a variety of factors,
including ribbon type, media and the condition of the printhead. You may adjust the
darkness for consistent high-quality printing.