Page 4-92 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 4 PREVENTIVE AND CORRECTIVE MAINTENANCE
%ODFN0DUN6HQVRU5HSODFHPHQW
5HSODFH%ODFN0DUN6HQVRU
1. Refer to RRP No. 1 on page 4-10 and place the power switch in the Off (O) position
and disconnect the AC power cord. Disconnect the data cables.
2. Refer to RRP No. 2 on page 4-12 and remove the electronics cover.
3. Refer to Figure 4-71. Remove two screws that secure the black mark sensor, and
remove the sensor.
4. Refer to Figure 4-4 or Figure 4-5. Follow the sensor leads back to the main logic board.
Cut and replace the plastic wire ties as necessary. Remove the hex nuts holding the
white cable clamps.
5. Disconnect the sensor connector from the main logic board.
6. Fasten the sensor in position with two screws.
7. Refer to Figure 4-4 or Figure 4-5. Route and secure the sensor electrical lead as neatly
as possible to the main logic board. Secure the flat white cable clamps with hex nuts.
Replace plastic wire ties as necessary.
8. Plug sensor electrical lead into the connector on the main logic board.
9. Reinstall the electronics cover.
10. Open the printhead and reinstall the media and ribbon. Close the printhead.
11. Reconnect the data cables and the power cord.
Figure 4-71. Black Mark Sensor Installation
Black Mark
Sensor
Allen Screws (2)
Page view 177