Page 4-36 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 4 PREVENTIVE AND CORRECTIVE MAINTENANCE
2. Refer to Figure 4-24 and locate the upper media sensor.
3. Carefully loosen, but do not remove, the screw at the top of the sensor.
NOTE: When using label stock that has a web between labels, position the upper
media sensor anywhere along the web, except where the rounded corners
of the label are detected. When using tag stock, position the upper sensor
directly over the hole or notch.
4. Slide the upper sensor along the slot to the desired position.
5. Tighten the screw to secure the sensor.
Use the following procedure to adjust the lower transmissive media sensor:
1. Refer to Figure 4-25 and locate the lower media sensor assembly under the rear idler
roller.
2. Position the sensor by sliding it in its slot, so that the two infrared emitters are directly
centered under the upper sensor.
3. Gently pull wires out as required. Wires should have a little slack.
NOTE: If moving the sensor results in a large loop of wires, dress the wires so
that they will not contact any moving parts, media, or ribbon.
Figure 4-24. Upper Transmissive Media Sensor Position Adjustment
Figure 4-25. Lower Transmissive Media Sensor Position Adjustment
Upper Media Sensor
Adjustment Screw
Lower Media Sensor
Page view 121