Page 4-56 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 4 PREVENTIVE AND CORRECTIVE MAINTENANCE
5. Fold the top of the insulation shield back into place and dress the harness so it does
not interfere with the reinstallation of the electronics cover.
6. Reinstall the electronics cover.
7. Reconnect the power cable to the power source. Place the power switch in the On (I)
position.
NOTE: If AC power is not restored to the printer, make sure that the power cable
is connected to a live power source. If the power source is live and the
printer does not power on, the AC/DC power supply might have failed.
&XWWHU&RPSRQHQWV
&XWWHU0DLQ/LQN5HSODFHPHQW
1. Refer to RRP No. 1 on page 4-10 and place the power switch in the Off (O) position
and disconnect the AC power cord. Disconnect the data cables.
2. Refer to RRP No. 2 on page 4-12 and remove the electronics cover.
3. For printers with configuration number 10500-0XXX-XXXX or 10500-1XXX-XXXX,
refer to RRP No. 3 on page 4-13 and remove the DC power supply.
or
For printers with configuration number 10500-2XXX-XXXX or 10500-3XXX-XXXX,
refer to RRP No. 5 on page 4-16 and remove the AC/DC power supply.
4. Refer to Figure 4-43. Remove the E-ring that attaches the cutter main link to the short
arm side of the cutter slotted link.
5. Remove the E-ring that attaches the cutter main link to the arm on the cutter assembly.
6. Ensure that the pivot pin remains in the slotted link, and remove the cutter main link.
NOTE: The notch in the main link must be at the top and face toward the back of
the printer.
7. Position the new cutter main link to the cutter assembly and the pivot pin in the slotted
link.
8. Secure both ends with E-rings.
9. Reinstall the DC power supply or the AC/DC power supply, depending on configuration.
10. Reinstall the electronics cover.
11. Reconnect the data cables and the power cord.
12. Reconnect the power cable to the power source. Place the power switch in the On (I)
position.
WARNING:
WEAR PROTECTIVE EYE WEAR WHEN REMOVING E-RINGS, C-CLIPS,
SNAP RINGS AND SPRINGS. ALL OF THESE ARE UNDER TENSION AND
COULD FLY OFF WHILE BEING REMOVED.