Page 2-24 105SL Maintenance Manual 32056L Rev. 2 12/4/01
SECTION 2 OPERATION OVERVIEW
,1,7,$/32:(583
After you have correctly installed the media and ribbon, set the power switch to the on (1)
position. The printer performs a Power On Self-Test (POST). When this is complete, the
display shows, “PRINTER READY”.
&$/,%5$7,21
NOTE: This procedure must be performed when the printer is first installed or if it
does not properly detect the top of the label.
To calibrate the printer, you must do the following:
Determine the type of media or labels being used.
•Chose the print method.
Position the media sensors, if necessary.
Configure the printer and software or driver based on the label being used.
Perform a media and ribbon calibration.
•Print a test label.
Two types of calibrations can be performed by the printer:
Type 1 — Auto Calibration: The 105SL printer auto calibrates on power up. Turning the
printer on causes the printer to feed media and ribbon and set the values it detects. This
includes media, media backing material (the spaces between labels), media out, and ribbon
in/out status. This form of calibration also occurs as part of the “Media and Ribbon
Calibration” procedures.
Type 2 — Manual Calibration (using non-continuous media): Performing the “Media and
Ribbon Calibration” procedure, below, first resets the sensitivity of the sensors to better
detect the media and ribbon you are using. With the sensors at their new sensitivity levels,
the printer then performs the standard calibration described above. Changing the type of
ribbon and/or media may require this calibration process to reset the sensitivity of the media
and ribbon sensors. Indications that the sensitivity may need to be reset would be a
“CHECK RIBBON” light ON with the ribbon properly installed or non-continuous media being
treated as continuous media.
0HGLDDQG5LEERQ&DOLEUDWLRQ0DQXDO3URFHGXUH
NOTE: The following procedure is used to adjust the sensitivity of the media and
ribbon sensors. It must be followed exactly as presented. All steps must
be performed even if only one of the sensors requires adjustment.
1. Press SETUP/EXIT key. Press NEXT/SAVE key until Media and Ribbon Calibrate
appears.
0(',$$1'5,%%21
&$/,%5$7(