22 Zebra XiIII-Series User’s Guide
When communicating via the parallel
port (refer to Figure 14), the
previously mentioned parameters are
not considered. Refer to page 51 to
configure the communication
parameters for the printer. The values
selected must be the same as those
used by the host equipment connected
to the printer.
For serial and parallel pinout and
technical information, refer to
“Appendix” on page 93.
Figure 14
&DEOLQJ5HTXLUHPHQWV
Data cables must be fully shielded and fitted with metal or metalized
connector shells. Shielded cables and connectors are required to prevent
radiation and reception of electrical noise.
To minimize electrical noise pickup in the cable:
Keep data cables as short as possible.
Do not bundle the data cables tightly with the power cords.
Do not tie the data cables to power wire conduits.
NOTE: Zebra printers comply with FCC “Rules and Regulations”,
Part 15, Subpart J, for Class A Equipment, using fully shielded
6' data cables. Use of longer cables or unshielded cables may
increase radiated emissions above the Class A limits.
RS-422 and RS-485 applications should use twisted shielded
pairs as recommended in the Appendix of the TIA/EIA.-485
Specification.