84 Zebra XiIII-Series User’s Guide
FEED Key Self Test
See Figure 35.
1. Turn off the printer.
2. Press and hold the FEED key
while turning on the power.
The FEED key self test prints out at
various darkness settings above and
below that of the darkness value
shown on the configuration label.
Look at these labels and determine
which one has the best darkness
setting for your application. This
value can be entered into the printer
by setting the darkness during the
configuration procedure. Refer to
page 44 for more information.
Figure 35
The value printed on that label is added to (plus) or subtracted from
(minus) the darkness value specified on the configuration label. The
resulting numeric value (0 to 30) is the best darkness value for that specific
media/ribbon combination.