Mode Protection
The ^MP (Mode Protection) instruction is used to disable the various
Mode functions on the front panel. Once disabled, the settings for the
particular mode function can no longer be changed and the LED
associated with the function will not light.
Since this instruction has only one parameter, each mode will have to
be disabled with an individual ^MP instruction.
The format for the ^MP instruction is:
^MPa
where
^MP = Mode Protection
a = Mode to Protect
Default value: No changes
Other acceptable values:
D = Disable Darkness Mode
P = Disable Position Mode
C = Disable Calibration Mode
E = Enable All Modes
S = Disable all Mode Saves. (Modes can be
adjusted but values will not be saved.)
Effective for Version 18.6.0
Default value: E = Enable All Modes
Other values: W = Disable Pause Key
F = Disable Feed Key
X = Disable Cancel Key
M = Disable Menu Changes
(Instruction ignored if parameter missing or incorrect.)
Example:
^XA^MPD^MPC^XZ
294 ZPL II COMMAND REFERENCE
^MP