Effective for Version 18.6.0
a = Applicator Mode
Factory Default: 0 Off - The auxiliary port output signal is
not provided for the applicator.
Initial Value at Power-up: The last value saved.
Other Values:
0. Off - The ~END_PRINT output signal is not active in
mode zero and the output remains deasserted HIGH, re-
gardless of printer activity. The ~START_PRINT input sig-
nal is also ignored in mode 0.
1. Mode 1 - The ~END_PRINT output signal is asserted
LOW only while media is moving forward.
2. Mode 2 - The ~END_PRINT output signal is asserted
HIGH only while media is moving forward.
3. Mode 3 - The ~END_PRINT output signal is asserted
LOW for 20 milliseconds when a label has been completed
and positioned. Not asserted during continuous printing
modes.
4. Mode 4 - The ~END_PRINT output signal is asserted
HIGH for 20 milliseconds when a label has been completed
and positioned. Not asserted during continuous printing
modes.