Battery Status
When the Battery Status command, ~HB, is sent to the Zebra printer,
a data string is sent back to the Host. The string starts with an <STX>
Control Code and is terminated by an <ETX><CR><LF> Control
Code sequence.
Data String
<STX>bb.bb,hh.hh,bt<ETX><CR><LF>
bb.bb = current battery voltage reading to nearest ¼ volt
hh.hh = last head voltage reading under load to nearest ¼ volt
bt = battery temperature
236 ZPL II COMMAND REFERENCE