Zebra A300 Specifications Page 144

  • Download
  • Add to my manuals
  • Print
  • Page
    / 396
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 143
The format for the ^BD instruction is:
^BDm,n,t
where
^BD = MaxiCode Bar Code
m = Mode
Default value:
2 Structured Carrier Message - Numeric Postal
Code (US)
Other values:
3 Structured Carrier Message - Alphanumeric
Postal Code (Non-US)
4 Standard Symbol, SEC
5 N/A
6 Reader Program, SEC
NOTE: Mode 0 and mode 1 are obsolete. Mode 0, if
used, will default to mode 2; mode1 defaults to mode 4.
Effective for Versions 14.8.0, 18.8.0, 21.8.0, 23.8.1,
23.8.2, 25.8.1, 25.8.2, 22.8.5
Mode 5 = Full EEC
n = Symbol Number
Default value: 1
Other values: 1 to 8 symbols may be added in a
structured document
t = Total Number of Symbols
Default value: 1
Other values: 1 to 8, representing the total number of
symbols in this sequence
Special considerations for the ^FD instruction when
using MaxiCode
The ^FD statement is divided into two parts: a High Priority Message
(hpm) and a Low Proirity Message (lpm). There are two types of High
Priority Messages. One is for a US Style Postal Code, the other is for
a Non-US Style Postal Code. The syntax for either of these High Pri-
ority Messages must be exactly as shown or an error message will be
generated. The format is shown on the next page.
ZPL II COMMAND REFERENCE 135
C
O
M
M
A
N
D
R
E
F
E
R
E
N
C
E
Page view 143
1 2 ... 139 140 141 142 143 144 145 146 147 148 149 ... 395 396