The ^JU (Configuration Update) instruction sets the active configura-
tion for the printer.
There are three choices for this instruction. They are defined as
follows:
S = Save Current Settings
The current configuration will be saved. This is the configuration
that will be used at Power-On.
F = Reload Factory Values (Default)
The factory values (default values) will be loaded.
(These values will be lost at Power Off if they are not saved with
the ^JUS instruction.)
R = Recall Last Saved Values
The last values saved using this (^JU) instruction or the Mode
Sequencing from the front panel will be loaded.