Zebra CPCL Specifications Page 438

  • Download
  • Add to my manuals
  • Print
  • Page
    / 497
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 437
Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-212
continued
internal_wired.ip.port
type: getvar; setvar
This parameter refers to the internal wired print servers port number that the TCP print service is
listening on. Noarmal TCP communications from the host should be directed to this port.
getvar result The currrent internal wired print server TCP/UDP port number.
Example
Description
Gets the printer to respond with internal wired print server TCP/
UDP port number.
Syntax ! U1 getvar ”internal_wired.ip.port
Result “ 9100
setvar choices
Values: 1-65535 (excluding any ports currently used by other services, such as 21,
23, 80, and 515).
Default 9100 “
Example
Description
Instructs the printer to change its internal wired print server TCP/
UDP port number.
Syntax ! U1 setvar “internal_wired.ip.port” “9100
Page view 437
1 2 ... 433 434 435 436 437 438 439 440 441 442 443 ... 496 497

Comments to this Manuals

No comments