Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-227
continued
internal_wired.ip.default_addr_enable
type: getvar; setvar
This parameter allows you to default the internal wired print servers IP address.
getvar result
The status of the setting of the internal wired print server’s default IP address
feature.
Example
Description
Gets the printer to show the status of the setting of the internal
wired print server’s default IP address feature.
Syntax ! U1 getvar ”internal_wired.ip.default_addr_enable
Result “on“
setvar choices
Values: “on” = enabled; “off” = disabled
Default “on”
Example
Description
Instructs the printer to use its default address if no address is
provided through DHCP or BOOTP. If you do not assign an IP
address after 2 minutes, the 10/100 Internal PS defaults to IP
address 192.168.254.254.
Syntax ! U1 setvar “internal_wired.ip.default_addr_enable” “on”
Page view 452