odometer.media_marker_count2
type: getvar; setvar
This parameter refers to the value of the second (count2) user resettable counter. The user resettable
counters track how much media has passed through the printer in both inches and centimeters.
getvar result This will return the current value of the second user resettable counter.
Example
Description Gets the current value of the second (count2) user resettable
counter in both inches and centimeters.
Syntax ! U1 getvar “odometer.media_marker_count2
Result 0”
setvar choices
Values: “0” = reset the counter
Default Must be an accepted value or it is ignored
Example
Description Resets the first user resettable counter.
Syntax ! U1 setvar “odometer.media_marker_count2” “0
odometer.headclean
type: getvar; setvar
This parameter refers to the head clean odometer count. This counter tracks how many inches and
centimeters have passed through the printer since the head was last cleaned.
getvar result This will return the values for the head clean counter.
Example
Description Gets the values for the head clean counter.
Syntax ! U1 getvar “odometer.headclean”
Result 0”
setvar choices
Values: “0” = reset the counter
Default Must be an accepted value or it is ignored
Example
Description Resets the head clean counter.
Syntax ! U1 setvar “odometer.headclean” “0