Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-75
continued
power.low_battery_timeout
type: getvar; setvar
This parameter refers to the low battery timeout. When the printer reaches the low battery state this
timeout will become active. The printer will shut down after the specified low battery time out
getvar result Current low-battery timeout in seconds.
Example
Description Get current low-battery timeout
Syntax ! U1 getvar “power.low_battery_timeout
Result 60
setvar choices
“0” through “65535”. Values are specified in seconds. A value of “0” disables low-
battery timeout.
Default 60”
Example
Description Set low-battery timeout to 60 seconds
Syntax
! U1 setvar “power.low_battery_timeout” “60
Result Printer low-battery timeout will be set to 60
power.low_battery_shutdown
type: getvar
This parameter refers to the low battery shutdown level.
getvar result Current low-battery shutdown level in volts.
Example
Description Get current low-battery shutdown level
Syntax
! U1 getvar “power.low_battery_shutdown”
Result 6.47(166)”