Section 14
Configuration/
Control
Commands
pg. 14-175
continued
wlan.ip.timeout.value
type: getvar; setvar
This parameter refers to the number of seconds before the connection times out for the wireless print
server.
getvar result Time before connection times out.
Example
Description Gets the time (in seconds) before the connection times out.
Syntax ! U1 getvar “wlan.ip.timeout.value”
Result 300
setvar choices
Values: “1” through “3600
Default 300
Example
Description Sets the time value (in seconds) of the wireless print server
before the connection times out.
Syntax ! U1 setvar “wlan.ip.timeout.value” “300