power.dtr_power_o
type: getvar; setvar
This parameter refers to the remote printer power control. DTR power off is used for power
management. When DTR is enabled the printer can be powered on and off via the DSR signal. When DTR-
power off is enabled, a low to high transition will cause the printer to turn ON and a high to low transition
will cause the printer to turn OFF. The printer will stay ON as long as DSR is high unless it reaches low
battery shutdown or receives a command to shut down.
NOTE: The inactivity time-out is disabled while DSR is active.
getvar result Current DTR power-off setting.
Example
Description Get current DTR power-off setting.
Syntax ! U1 getvar “power.dtr_power_off
Result on”
setvar choices
“on”, “off
Default “on”
Example
Description Enable DTR power-off.
Syntax ! U1 setvar “power.dtr_power_off” “on”
Result Printer will enable DTR power-off
power.full_charge_capacity
type: getvar
Returns the predicted pack capacity in mA-Hour when it is fully charged.
getvar result Returns the predicted capacity of the battery pack in mAh.
Example Syntax !U1 getvar “power.full_charge_capacity
This parameter will only function on printers equipped with a Zebra “Smart Battery.