Page view 288
Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-63
continued
netmanage.avalanche.text_msg.print
type: getvar; setvar
This parameter sets and gets Network Management Text Message Print enable setting
getvar result Returns the current Network Management Text Message Print enable
setting.
Example
Description
This example retrieves the device’s Network Management
Text Message Print enable setting
Syntax
! U1 GETVAR “netmanage.avalanche.text_msg.print
Result off
setvar choices
“on”, “off
Default “off
Example
Description
This example sets the device’s Text Message Print enable
setting
Syntax
! U1 SETVAR “netmanage.avalanche.text_msg.print” “on”
Result None
netmanage.avalanche.udp_timeout
type: getvar; setvar
This parameter obtains or sets the device’s Network Management UDP timeout. Time is set in
milliseconds.
getvar result Gets current Network Management UDP time-out setting
Example
Syntax ! U1 GETVAR “netmanage.avalanche.udp_timeout
setvar result Sets Network Management UDP time-out in msec.
Example
Syntax
! U1 SETVAR “netmanage.avalanche.udp_timeout” “200
Result UDP timeout set to .2 sec.