Mobile Printing Systems
CPCL Programming Manual
Section 10
Advanced
Utilities
pg. 10-51
continued
BHT PROTOCOL Command
This command placed in an autoexec. bat file overrides the default method of communication.
BHT-PROTOCOL CABLE enables BHT or BHT-IR protocol via cable. If the BHT-PROTOCOL CABLE
command is not present, data is sent “raw” over the serial cable, if it is detected the BHT-PROTOCOL BHT
command sends data in the BHT mode; BHT-PROTOCOL BHTIR sends data in the BHT-IR mode.
Format:
{Command} {mode}
where:
{Command}: BHT-PROTOCOL
{mode}: BHT: This mode establishes that data will be sent in BHT protocol mode
CABLE: This mode enables BHT or BHT-IR protocol via cable. If the BHT-PROTOCOL CABLE
command is detected the BHT-PROTOCOL BHT command sends data in the BHT mode
BHTIR: Sends data in the BHT-IR mode.