Page view 80
Front Panel Controls
Front Panel LCD
23063L-001 Rev. 2 6/21/2004 RXiIIIPlus User Guide 57
WEB S.
These parameters are automatically set during the calibration procedure. They should be
changed only by a qualified service technician. See the Maintenance Manual for more
information on these parameters.
Press NEXT/SAVE to scroll through these parameters.
MEDIA S.
RIBBON S.
MARK S.
TAKE LABEL
MARK MED S.
MEDIA LED
RIBBON LED
MARK LED
LCD ADJUST
LCD Adjustment
This parameter allows you to adjust the contrast of your LCD if it is difficult to read.
1. Press the left oval to move the cursor.
2. Press the right oval to toggle +/- or to increase the value of the digit.
Range: 00 to 19
FORMAT
CONVERT
Format Convert
Selects the bitmap scaling factor. The first number is the original dots per inch (dpi) value;
the second, the dpi to which you would like to scale.
Note • Not applicable on all printers.
Press the right or left oval to display other choices.
Default: None
Selections:
None, 150 300, 150 600, 200 600, 300 600
IDLE DISPLAY
Idle Display
This parameter selects the LCD options for the real-time clock.
Note • If the default value is not selected, pressing either oval briefly displays the
firmware version of the printer.
Press the right or left oval to display other choices.
Default: Firmware version
Selections: mm/dd/yy (24 hour), mm/dd/yy (12 hour), dd/mm/yy (24 hour), dd/mm/yy
(12 hour)
RTC DATE
RTC (Real-time clock) Date
This parameter allows you to set the date following the convention selected in
IDLE
DISPLAY
.
1. Press the left oval to move to the next digit position.
2. Press the right oval to increase the value of the digit.
Table 5 • Printer Parameters (Sheet 14 of 15)