Zebra 105SL User Manual Page 61

  • Download
  • Add to my manuals
  • Print
  • Page
    / 130
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 60
Printer Operation
Adjust and Calibrate Sens ors
11342L Re v. 8 6/4/2004 105SL User Guide 37
7. Close the printhead, trapping the ribbon in this position.
8. Press the (+) key. The LCD shows “CALIBRATING PLEASE WAIT.”
9. When this part of the calibration process is completed, the LCD reads “RELOAD ALL
CONTINUE.”
10. Open the printhead. Pull the liner until a label is positioned between the media sensors.
11. Return the ribbon to its proper position.
12. Close the pri nthead. Press th e (+) key to perform t he next part of t he calib ration sequence.
“MEDIA AND RIBBON CALIBRATE” displays. The printer is calibrated when the
media stops feeding.
13. Press SETUP/EXIT to leave Setup Mode. Choose “pe rma nen t” whe n SAVE CHANGES
displays.
14. Press NEXT/SAVE to save the changes.
The printer does a calibration equivalent to pressing
CALIBRATE; during th is process,
the printer de termines the la bel length. To see the new readings on th e new scale, prin t a
sensor profile.
Page view 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 129 130

Comments to this Manuals

No comments