Programming
Software Command Syntax
09/28/2009 TTP 2100 Technical Manual P1003640-002
This command scales the height of the text printed by a factor of up to 16x. The valid range of
values is 0 to 15.
In combination with variable character width (ESC w n1), give highly legible characters
depending on the font to which the command has been applied.
Different heights can be mixed on the same print line.
This command scales the width of the text printed by a factor of up to 8x. The valid range of
values is 0 to 7.
In combination with variable character height (ESC w n1), give highly legible characters
depending on the font to which the command has been applied.
Different widths can be mixed on the same print line.
ESC h n1
Text Height
1B 68 n1 hex
27 104 n1 decimal
n1 = 0 Resets the character height to the base character height
n1 = 1...15 Increases the character height to 2...16 times the base character height.
ESC w n1
Text Width
1B 77 n1 hex
27 119 n1 decimal
n1 = 0 Resets the character width to the base character width
n1 = 1...7 Increases the character width to 2...8 times the base character width.
Important • Use of the multiple width function when printing bar codes is not recommended
as the text data may become illegible.