Page view 27
AUTOFR - Au to matic Form Print ing Fea ture
AUTOFR treats any in com ing data as a vari able in -
tended for print ing. This means if you send the
printer a mem ory par ti tion com mand, the la bel will
print, if you send a de lete com mand - the la bel will
print! So, while you are test ing AUTOFR it is best to
use an other name for the form. Once you are sat is -
fied with the form, re name it AUTOFR be fore you
down load it. There is no need to spec ify a file ex ten -
sion.
Isolating Data From
the Input Device
Place the printer in the di ag nos tic dump mode
and send from your data in put de vice.
All char ac ters the de vice sends will be printed
on the la bel.
If noth ing prints, noth ing is ar riv ing - check
pin-outs and se rial set tings.
Disabling AUTOFR Send a XOFF data char ac ter (13 hex. or ASCII
19) or a NUL (00 hex. or ASCII 0) to the printer.
The form may now be de leted from the printer.
Removing AUTOFR The pro gram mer must send a De lete Form - FK
com mand to the printer af ter dis abling
AUTOFR.
Example:
FK"AUTOFR"¿
FK"AUTOFR"¿