A Com mand - ASCII TEXT
Simple Expressions
in Data Fields
An ad vanced func tion of the A com mand al -
lows ad di tion and sub trac tion to be per formed
on con stant and vari able val ues in flash print ers.
Syntax Ap
1
,p
2
,p
3
,p
4
,p
5
,p
6
,p
7
,“DATA”[p
8
p
9
p
10
…]
Parameters For the p
1
- p
7
and “DATA” pa ram e ters -
See first page of A com mand, page 3-4.
p
8
= Re quired. Must be a vari able data field
num ber, e.g. V00, V01 etc.
p
9
= Re quired. Op er a tor, + or –
p
10
= Re quired. Vari able data field num ber
or con stant value.
Valid Num ber Ranges:
Con stant = 0 to 2147483647
Vari able = 0 to 2147483647
Re sult = -2147483648 to 2147483647
❏ The Ex pres sion must start with a vari able
field.
❏ The char ac ter field length de fined for the first
vari able in the ex pres sion will be used to for -
mat the re sult. If the re sult is of a greater
length than the de fined char ac ter length, then
the re sult field will con tain ‘X’s.
❏ A syn tax er ror will be gen er ated dur ing form
storage if the con stant value is too large.
❏ If an er ror oc curs dur ing the eval u a tion of the
ex pres sion, the re sul tant field will be filled
with ‘X’s.
980352-001 Rev.D 3-7