oW Command - Customize Bar Code Parameters
Description: This com mand al lows the ad vanced pro gram -
mer to mod ify spe cific bar code pa ram e ters to
ex ceed the spec i fied bar code’s de sign tol er -
ances, i.e. re duce the bar code size.
Using the oW com mand may cause bar codes to be -
come un read able by some or all bar code scan ners.
Syntax: oWp
1
,p
2
,p
3
,p
4
,p
5
Parameters: p
1
= Ini tial width nar row white bar.
De fault value is 2
p
2
= Ini tial width nar row black bar.
De fault value is 2
p
3
= Ini tial width wide white bar.
De fault value is 4
p
4
= Ini tial width wide black bar.
De fault value is 4
p
5
= Ini tial bar code gap.
De fault value is 3
The oW com mand is a global printer com -
mand.
They can not be is sued in side of a form.
They must be is sued prior to is su ing a bar
code com mand (and print ing).
Use only one bar code for mat. Using more
than one bar code may cause un pre dict able
re sults or op er a tion.
Is sue all 5 com mand pa ram e ters (p1-5 ). Use
the de fault pa ram e ter val ues as place hold -
ers.
Bar code printed with this com mand should
be printed in the picket fence ori en ta tion (0º
& 180º ro ta tions) to max i mize scan ning.
3-82 980352-001 Rev.D