Zebra EPL2 Specifications Page 43

  • Download
  • Add to my manuals
  • Print
  • Page
    / 154
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 42
b Command - 2D Bar Code - MaxiCode Specific Options
Description Use this com mand to gen er ate MaxiCode bar
code sym bols with a sin gle com mand. The
printer will au to mat i cally in ter pret and en code
data into MaxiCode sym bols for data modes 2,
3, 4, and 6. Up to eight sym bols can be linked.
Syntax bp
1
,p
2
,p
3
,[p
4
,][p
5
,]“DATA”
Parameters p
1
= Hor i zon tal start po si tion (X) in dots
p
2
= Ver ti cal start po si tion (Y) in dots
p
3
= M - Must be “M” for MaxiCode
p
4
= Mode Se lec tion
Value De scrip tion
Not Used Au to matic Se lec tion Mode 2 or 3
M2 Mode 2
M3 Mode 3
m4 Mode 4
m6 Mode 6
1. If p
4
(Mx) is not used, the printer will use the
fol low ing rules to au to mat i cally for mat the
DATA” pa ram e ter. If the postal code (third
parameter, PC) in the “DATA” is:
All nu meric char ac ters, the printer will au to -
mat i cally se lect Mode 2.
Al pha only or al pha-nu meric char ac ter com -
bi na tions will set the printer to Mode 3.
Not used, the printer au to mat i cally se lects
Mode 3.
2. If p
4
value is “M2 or M3”, the printer will use
the fol low ing rules to for mat the “Data” pa ram -
e ter:
In Mode 2 - If a non-nu meric char ac ter is en -
tered in the Postal Code “Data” pa ram e ter field,
then the MaxiCode bar code will not print.
In Mode 3 If the Postal Code “Data” field
ex ceed 6 char ac ters, then the ad di tional char -
ac ters will be trun cated from the bar code field.
980352-001 Rev.D 3-25