GM Command - Store Graphics
Description Use this com mand to store PCX graph ics files in
mem ory.
Syntax
GM"NAME"p
1
¿
“DATA”
Parameters “NAME” = This is the graphic name that will
be used when re triev ing the stored
graphic.
• The name may be up to 8 char ac ters long.
• Graphic names stored by the printer are case
sen si tive and will be stored ex actly as en tered
with the GM com mand line; i.e. “LOGO1”,
“logo1” and “LoGo1” are three dif fer ent
graph ics when stored into the printer or when
re trieved by the user.
p
1
= This is the file size in bytes. Use the DOS
DIR com mand to de ter mine the ex act
file size.
“DATA” = Graphic data in 1-bit (black &
white) PCX (bi nary data) for mat file.
❏ A graphic will not store if suf fi cient mem ory is
not al lo cated to graphic mem ory. See the M
com mand for de tails on ad just ing and con fig -
ur ing mem ory to store graph ics (forms and
soft fonts).
❏ Ver ify the proper stor age of the graphic with
the GI com mand.
3-60 980352-001 Rev.D