B Com mand - RSS-14 Bar Code Spe cific Op tions
p
7
= Bar code height in dots. See the ta ble
above for the Min i mum Height Mul ti -
plier. The printer will au to mat i cally se -
lect the larger of of two val ues: 1) this
value and 2) the Se lected nar row bar
width (p
5
) times the Min. Height Mul -
ti plier listed in the ta ble for the se lected
RSS-14 bar code type (p
4
).
p
8
= Print hu man read able code.
Val ues: B=yes or N=no.
DATA” = Rep re sents a fixed data field of
nu meric data, 0-9 only.
The printer's data parser will al low the
use of lead ing ze ros (0's) or spaces
which will be dis carded when data is en -
coded in the bar code.
Value (P
4
) De scrip tion Max. Nu meric Value
R14 Ba sic RSS-14 9999999999999
RL Lim ited 9999999999999
RS Stacked 9999999999999
RT Trun cated 1999999999999
Data with the RTC
Time & Date
Functions
The “Data” field can be re placed by or com -
bined with the fol low ing vari ables:
TT = Prints the cur rent time at this po si tion in
the pre de fined for mat. See the TT com -
mand for for mat se lec tion. This vari able
is avail able only if the printer RTC Time
& Date op tion is in stalled.
TD =Prints the cur rent date at this po si tion in
the pre de fined for mat. See the TD com -
mand for for mat se lec tion. This vari able
is avail able only if the printer RTC Time
& Date op tion is in stalled.
Be cause the RSS-14 bar code sym bols only
sup port nu meric data, the time and date data
re called by the TD and TT com mands must not
in clude de lim it ers, i.e. "/,-, or :" or any other de -
lim it ers that may be set.