Default Parameter Settings
Print Setup
10/22/2008 TTP2100 Technical Manual P1003640-001
The sensor mask is set automatically at calibration. It will mask away all sensors seeing the
guide and is used for the virtual sensor “Paper before head” and will affect paper loading and
calibration start. Any raw value will not be affected by the mask.
Selects which sensor should be used for black mark / Gap detection.
62
9Default
TOF Sensor Mask
0 Min
255 Max
bit 0 Sensor BM1 in use (edge sensor for 82.5 mm paper)
bit 1 Sensor BM2 in use (center sensor)
bit 2 Sensor BM3 in use (sensor 17.5 mm from center)
bit 3 Sensor BM4 in use (sensor 12.5 mm from center)
bit 4 7 Reserved, shall be 0.
63
1Default
BM Sensor
0 Min
4Max
<ESC>&P<063><000> Auto, selects sensor BM1 or BM4 depending on paper width.
<ESC>&P<063><001> Force the use of sensor BM1 (edge sensor for 82.5 mm paper)
<ESC>&P<063><002> Force the use of sensor BM2 (center sensor)
<ESC>&P<063><003> Force the use of sensor BM3 (sensor 17.5 mm from center)
<ESC>&P<063><004> Force the use of sensor BM4 (sensor 12.5 mm from center)