Top of Form (TOF) Sensor
10/22/2008 TTP2100 Technical Manual P1003640-001
Calibrating the TOF Sensor
1. Open the printhead.
2. Remove ticket stock.
3. Hold the Feed button pressed and close the printhead (keeping the button pressed all the
time).
4. Release the button, the Status LED should be off.
5. Load ticket stock (just slide into the slot and let the printer auto load the paper).
The printer will forward the paper until it finds two TOF marks and then stop and save all
TOF-mark parameters
6. Now open the printhead and remove the ticket stock, close and feed the tickets in again
and the printer is ready for use.
Repeat this procedure if the procedure fails or if the printer should be used with tickets that
differ from the original specification.
Note • To ensure good calibration conditions, lightly press the ticket stock towards the
bottom of the input guide during calibration.