Summary of Firmware Release
V68.19.4Z
03/24/2014 P1040502-017
Mirror path
Mirror feedback path
Mirror appl path
Mirror mode
Consult the Programming Guide for more information.
Added a "default" field to the "allconfig" JSON response for each setting.
The Cloud Connect weblink connection will now send a websocket ping to the connected
server every 60 seconds. If no response is received after three attempts, the connection
will be closed.
The Cloud Connect weblink connection now logs the servers certificate serial number and
fingerprint.
Additional bits added to the ~HQES response and Advanced Discovery packet.
A new setting weblink.ip.connX.num_connections has been added. This
setting shows the number of established connections. The control channel counts as 1 as
well as all other sub channels (echo, raw_port, json_config). This is getvar only settings
with a max value that is the same as the max_number_connections. Consult the
Programming Guide for more information.
A new group of settings for position have been added. These allow users to manually set
latitude, longitude and altitude values on the printer. Consult the Programming Guide for
more information. The new settings are:
device.position.latitude
in degrees min/max: -90.0/90.0
device.position.longitude
in degrees man/max: -180.0/180.0
device.position.altitude
in meters min/max: -10000.0/406700000.0
device.position.accuracy
in meters min/max: 0.0/406700000
Issues Corrected
JSON will now return a null instead of a "?" for settings that do not exist on the device
The ip.dns.domain or ip.dns.servers values can now be set while IP
addressing is set to permanent.
PCX graphics handling has been improved to handle additional scenarios.
Scalable font field handling improved.
Handling of Bluetooth remote device disconnect events improved.
odometer.user_label_count can be set to "0".
Ping response times have been enhanced.
V68.19.4Z
Release Date: 10 June 2013
This firmware is for use with the following printer models:
QLn220
QLn320