Troubleshooting
Calibration Problems
9/6/07 XiIIIPlus/R110Xi/R170Xi User Guide 13383L-004 Rev. A
Calibration Problems
Table 14 identifies problems with calibration, the possible causes, and the recommended
solutions.
Table 14 • Calibration Problems
Problem Possible Cause Recommended Solution
Loss of printing
registration on labels.
Excessive vertical
drift in top-of-form
registration.
The platen roller is dirty. Clean the platen roller according to the
instructions in Clean the Printhead and Platen
Roller on page 134.
Media guides are positioned
improperly.
Ensure that the media guides are properly
positioned.
The Media type is set
incorrectly.
Set the printer for the correct media type
(non-continuous or continuous). See Set Media
Type on page 74.
Auto Calibrate failed. Media or ribbon is loaded
incorrectly.
Ensure that media and ribbon are loaded
correctly.
The sensors could not detect the
media or ribbon.
Manually calibrate the printer. See Calibrate
Media and Ribbon Sensor Sensitivity on page 85.
The sensors are dirty or
positioned improperly.
Ensure that the sensors are clean and properly
positioned.