CleaningtheCutterModule
(Forprintersequippedwiththeoptionalcutter.)
Iflabelsarenotbeingcutproperlyorifthecutterjamswithlabels,turnoff
theprinterpowerandunplugtheprinter.Then,cleanthestationarycutter
bladewithcleaningsolvent.Thiswillremovelabeladhesiveand/orpaper
debris.Iffurthercuttercleaningisnecessary,orifthecuttercontinuesto
performunsatisfactorily,contactanauthorizedservicetechnician.
Lubrication
CAUTION!Nolubricatingagentsofanykindshouldbeusedon
thisprinter!Somecommerciallyavailablelubricants
willdamagethefinishandthemechanicalpartsif
used.
FuseReplacement
Theprinterusesametric-stylefuse(5X20mmIEC)ratedatF5A,250V.
Theendcapsofthefusemustbearthecertificationmarkofaknown
internationalsafetyorganization(seeFigure37onpage92).Theprinter
comeswithtwoapprovedfuses:oneinthecircuitandoneinthe“spare
fuseholder.
1.Turnofftheprinterpowerandunplugthepowercordfromthebackof
theprinter.SeeFigure30.
2.Usingasmall-bladescrewdriverorsimilartool,removethefuseholder
fromtheprinter.
3.Removethefaultyfuseandinstallanewfuseofthecorrecttype.Refer
toFigure31.Thefusethatgoesintotheprinterfirstistheonethatis
“in-circuit.Ifyouusethesparefuse,besuretoorderareplacement
fuse(fusescanbeorderedfromyourZebradistributor).