TT Command - Define Time Layout
Description Use this command to define the time format
when printing.
Syntax TTp
1
[|p
2
|p
3
][+]
Parameters P
1
, P
2
, P
3
= h, m, or s
These parameters describe the format of
the time display.
·
At lease one parameter must be supplied.
·
Each parameter can be any of the values h,
m,ors and are described below.
Value Description
h
Hours displayed as 2 digits (e.g. 01)
m
Minutes displayed as 2 digits (e.g. 15)
s
Seconds displayed as 2 digits (e.g. 00)
[+] = Enable 12 Hour clock format
Appendinga+totheendofthecom-
mand string selects 12 hour clock mode.
The times will display with an “AM” or
“PM” indicator. Default (no +)=24
hour clock mode
| = Separator character
The separator may be any ASCII char
-
acter value between 032 and 063. The
separator character is printed between
the results of each of the supplied pa
-
rameters.
This command works only in printers equipped with
the Real Time Clock time and date option.
Examples: If the current time is 1:25 p.m.:
TTh:m:s+ : 01:25:00
TTh,m : 13,25
TTh+ : 01 PM
980009-001 Rev.F E-7