Zebra EPL2 Specifications Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 138
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
FS Command - Store Form
Description This command begins a form store sequence.
Syntax FS"FORMNAME"
Parameters “FORMNAME” =This is the form name that
will be used when retrieving the stored
form.
·
Thenamemaybeupto8characterslong.
·
Form names stored by the printer are case
sensitive and will be stored exactly as entered
on the FS command line; i.e. “FORM1”,
“form1” and “FoRm1” are three different
formswhenstoredintotheprinterorwhenre
-
trieved by the user.
·
Global commands such as EI, EK, ES, FI,
FK, GI, GK, GM, I, M, N, P, TS, U, UE,
UF,UG, Y,W,?, ^@ shouldnotbeusedin
a form store sequence.
Form name, AUTOFR, is reserved for automatic,
single form recall, see page 3-9 for details.
All commands following FS will be stored in
forms memory until the FE command is re-
ceived, ending the form store process.
Delete a form prior to updating the form by
using the FK command. If a form (with the
same name) is already stored in memory, is
-
suing the FS command will result in an error
and the previously stored form is retained.
To print a list of the forms currently stored in
memory, use the FI command.
A form will not store if sufficient memory is
not allocated to form memory. See the M
command for details on adjusting and con
-
figuringmemorytostoreforms(graphicsand
soft fonts).
980352-001 Rev.A
3-45